Delta Medical Corporation

Line Frequency - High Powered X-Ray

  • Digital Display for Line Input Voltage, Supporting user to operate at 220V for accuratr results.
  • Microprocessor Based Overload Protection for 100% safety.
  • Microprocessor Based Electrnic Exposure Control for Accurate exposure to the level of Micro Secs.
  • Digital Display for mAs, kVp, Technic, X-Ray ON & Overload Protection.
  • Automatic Overload protection with visual & audible indication for longer life of the Tube.
  • Automatic cutoff for High Input Voltage.
  • mAs... Each Step of 2 mAs, thereby giving much higher Timer combinations.
  • Illuminated Front Panel for easy selection even in dim Lit roams.
  • Soft Touch keys for ON/OFF, mAs selection, selection, Bucky selection, Radiography/Fluoroscopy selection & Exposure.

Model

AE 500 (500mA X-Ray System)
Technical Specifications 500MA
Power Requirement 3 Phase, 415V.(36 KW)
Generator Type 2 Pulse, Full Wave Rectified.
kVp Range 40–125 kVp (Single Step) for Radiography
40–100kVp (5kVp Step) for Fluoroscopy
Fluoroscopic mA< 0 to 3.0mA
Radiographic Rating 50mA, 100mA on small focus
200mA, 300mA, 400m and 500mA on Large focus.
mAs 4-500mAs (Each Step of 2mAs)>
Fluoroscopic Timer 5 minutes cumulative(With audible Alarm)
Radiographic Timer Automatic Selection by Microprocessor
(Using Combination of mAs & mA)
Tube Type Unit Compalible Double fous Rofaling
Anodetbe(BEL/Toshiba)
Soft Touch Key Board Illuminated Digital Display For, mAs, mA, Rad/Flu,
Bucky ON/OFF, ON/OFF, READY & Exposure.
DIGITAL DISPLAY For kVp, mAs, mA, X-Ray ON, Overload.
 
Options Compatible Table
500mA Radiographic Unit. Horizontal Table.
500mA Radiographic/Fluoroscopic Unit. Manual Tilt 5 Position Table.
6"IITV/9"IITV Attachment Motorized Table With SFD.
Floating Table Top Table.
Vertcal bucky
Download Brochure
AE 800 (800mA X-Ray System)
Technical Specifications 800MA X-Ray Machine
   
Power Requirement 3 Phase, 415V.(64 KW)
Generator Type 2 Pulse, Full Wave Rectified.
kVp Range 40–125kVp (Single Step) for Radiography
40–100kVp (5kVp Step) for Fluoroscopy
Radiographic Rating 100mA, 200mA on small focus
300m, 400mA, 600mA and 800mA on Large focus.
mAs 4-500mAs (Each Step of 2mAs)
Radiographic Timer Automatic Selection by Microprocessor
(Using Combination of mAs & mA)
Tube Type Unit Compatible Double focus Rotating Anode Tube
Soft Touch Key Board Illuminated Digital Display For, mAs, mA, Rad/Flu,
Bucky ON/OFF, ON/OFF, READY &Exposure.
DIGITAL DISPLAY For kVp, mAs, mA, X-Ray ON, Overload.
   
Options Compatible Table
800mA Radiographic Unit. Manual Tilt 5 Position Table.
800mA Radiographic/Fluoroscopic Unit. Motorized Table With SFD.
6"IITV/9"IITV Attachment Floating Table Top Table.
Vertcal bucky
   
Download Brochure